How do you get a level 3 NDT?
To get a Level 3 NDT certification, technicians must complete education, training, and industry-specific work experience with an NDT inspection service provider, and pass both written and practical exams. For ET (Eddy-current or Electromagnetic Testing), RT (Radiography Testing), and UT technicians (Ultrasonic Testing, including PAUT inspection), a Level 3 certification requires eighteen months of practical work experience. For MT (Magnetic Particle Testing), PT (Liquid Penetrant Testing) and VT (Visual Testing) technicians, twelve months of experience is necessary before completing examinations. As the highest level of certification, Level 3 candidates must provide a record of their experience to their certification body in the form of a CV (curriculum vitae).